BIL = Rated lightening impulse withstand voltage ( For 220kV BIL is 1050 kV/m For 66kV BIL is 450 kV/m ) Is = 9.7 kA. Now, the allowable strike distance is. S = 8 x k x Is. Where, k = Strikes on shield wire (value for mast is 1.2 for earthig wire is 1) S = 25.007m. H = Height of equipment is. H = 12.50m. A = Height of object to be

[email protected]
News Detail
  • General Technical Specification For 220kV SF6 GIS

    Dec 23, 2017SF6 GIS. The SF6 gas insulated metal enclosed switchgear shall be totally safe against inadvertent touch of any of its live constituent parts. It should be designed for indoor application

    Get Price
  • 400/220 kV SCADA controlled gis based

    400/220 kV SCADA controlled gis based TRANSMISSION SUBSTATION OPERATED BY Submitted in the Month of August, 2013 by Under the Guidance of Jayant Shekhar Dr. Rohit Verma Roll No. 36 Sh. H. H. Mahato Batch: 2012 – 2014 As part of MBA (Power Management) Curriculum ofFile Size: 1MB

    Get Price
  • ENERGY AUDIT APPLICATIONS

    May 14, 2018Why new 220kV GIS Grid Station constructed •Load growth increase. •DISCO LESCO load center is supplied by 220/132kV • Replacement of bridge rectifier in 11kV Panels for charging of the dc motor. • Laying of gravel in the 132kV switchyard upto mark.

    Get Price
  • Estimation of Transient over Voltages in Gas

    inception. Thus, it corresponds to the charge conducted through the spark channel up to time „t‟. The modeling diagram of 220kv GIS system as in the fig.,4 and the following arrangement is assumed for the developing the model and the are phenomena and gas insulated substation concepts can analysis by fig. 3 and fig 4 .

    Get Price
  • Gas-insulated switchgear up to 245 kV, 50 kA, 4000

    The Siemens gas-insulated switchgear (GIS) is an extremely successful product concept. Since its introduction back in 1968, Siemens has installed more than 28,000 indoor and outdoor switchgear bays world-wide, and well over 300,000 bay-years of operation have been recorded. Intense research and continuous further

    Get Price
  • Gas Insulated Switchgear - GE Grid Solutions

    XD|GE provides Gas Insulated Switchgear (GIS) solutions for high to ultra . high-voltage power transmission and distribution networks. We offer a highly reliable, compact GIS that lowers installation space. and reduces maintenance requirements. Designed with light-weight, durable aluminum enclosures, total load on the

    Get Price
  • Product brochure Gas-insulated switchgear ELK-14

    spring operating mechanism in our entire GIS portfolio from 72.5 kV to 1200 kV, and we have supplied more than 100,000 spring operating mechanisms of this type. Our spring operating mechanism is composed of a charging system, an energy storage with disk spring stack, an independent actuator piston and control valves,

    Get Price
  • AC High Voltage Circuit Breakers - Institute of

    (GIS). •Hybrid switchgear allows to reduce the size of substations and to combine the advantages of AIS and GIS. •Specific IEC standard: IEC 62271-205. •Circuit breaker is of GIS or Dead tank type •Depending on the capacitance of the liaison to overhead lines, it is considered as a GIS or AIS circuit breaker.

    Get Price
  • High-voltage substations | Power Transmission | Siemens

    The GIS helps provide additional load capacity and enhances safety and reliability by redundancy in the system design and earthquake resistance. Norway benefits from an additional feed-in of electricity provided by wind and small hydro power plants Statnett SF energy system operator | Sogndal substation, Norway Sogndal

    Get Price
  • 60-500 kV High Voltage full BD2 - Nexans

    GIS sealing ends 25 •Joints 26 200/345 (362) kV copper conductorThe designs 26 Straight ungrounded and grounded joint 26 Joint with screen separation 26 Transition joints 26 290/500 (550) kV copper conductorThe technologies 27 Taped joint 27 Premoulded joint 27 Prefabricated joint 27 Miscellaneous equipment 28

    Get Price
  • HIGH VOLTAGE XLPE CABLE SYSTEMS Technical

    2.2 Capacity, charging current The operating capacity depends on the type of insulation and its geometry. The following formula applies for all radial field cables: d D C r b ln 5.56 ( F/km) with r = Relative permittivity (XLPE: 2,4) D = Diameter over main insulation (mm) d = Diameter over inner semiconducter (mm)GIS

    Get Price
  • INDUSTRIAL TRAINING REPORT ON 400/220kV

    The GIS substation at Magarwada is basically a connector between two grids of 400 kV and 220 kV through Inter Connecting Transformers(ICT). The switching and fault protection are broadly done using GIS technology; which requires very less amount of space and maintenance cost. It also gives much better reliability for long period of

    Get Price
  • Circuit breakers | Transmission Products | Siemens

    The main components, such as the operating mechanism, control system, base frame, kinematic chain and insulator designs are identical and based on decades of manufacturing and operating experience. Our GIS switchgear range also includes the same interrupter units, operating mechanisms and control elements.

    Get Price
  • 220KV GIS SYSTEM.ppt | Electrical Substation | Insulator

    220kv gis bays 10adq03 -unit#1 rat bay adl31-tuticorin line bay 00 adq01 - csat bay adl15 - s.r.pudur line bay adq90 - bus coupler bay 20adq03 - unit#2 rat bay adl14 - spare line bay adq10 - ict#1 bay adq20 - ict#2 bay 220kv gis components. 220kv

    Get Price
  • High-Voltage Products

    GIS, minimizes the risk of failure • This ensures a failsafe product lifecycle of up to 50 years, including special applications, e.g., in high and low ambient temperatures or in earthquake-risk zones Customer partnership around the globe More than 136,000* circuit-breakers delivered to 150 countries with over 100 years of operational

    Get Price
  • Product Brochure Gas-insulated Switchgear ELK-14

    GIS for voltages from 72.5 kV to 1,100 kV. In 1969 ABB introduced one of the world’s first 245 kV transmission GIS. Subsequent generations featured horizon-tal puffer circuit-breakers and a low center of gravity which have reduce the impact of seismic activity. In 1993, ABB introduced the ELK-14-type GIS also rated at 245 kV, but

    Get Price
  • Nepal Electricity Authority Project Management

    400 kV(GIS)/220kV (GIS) New Khimti Substation,P- b page 5 of 7 As per the referred clause price schedule mentioned only Ventilation system for GIS hall. Please clarify type of ventilation system and stand by requirement for fan for GIS hall and provide detailed specification for the same. shall be as per the provision of the

    Get Price
  • Transient over Voltages under Line Fault Conditions

    GIS is a safe and highly reliable system, free of environmental hazards. The maximum magnitude of the transient over voltage is 2.0p.u. this value is largely dependent upon the level of trapped charge on the GIS bus bar existing at the time of the re-strike. The amplitude of trapped charge is strongly influenced by the

    Get Price
  • CENTRAL ELECTRICITY REGULATORY

    fresh petition for “500 MVA 400/220KV ICT-II at Baghpat GIS S/stn along with associated bays” and “7 numbers of 220 kV line bays at Baghpat GIS Sub-station” and held as under:- Quote “We have considered the Petitioners submission and are of the view that the Petitioner should file separate application for obtaining

    Get Price
  • Evaluation the High Voltage Gas Insulated Substations

    The relationship of the apparent charge and the amplitude of the time-domain signal, and the integral energy from 300 MHz to 1.6 GHz of the signal induced by PD in GIS are analyzed thoroughly.

    Get Price
  • Charging Current in Long Lines and High-Voltage

    Sep 14, 20121 Charging Current in Long Lines and High-Voltage Cables – Protection Application Considerations Yiyan Xue, American Electric Power Dale Finney and Bin Le, Schweitzer Engineering Laboratories, Inc. Abstract—In the analysis of power line protection behavior, the series impedance of the lumpedGIS

    Get Price
  • UHVAC Substation and Main Electrical Equipment -

    Jan 01, 2018In addition, such problems of the1100-kV GIS/HGIS as a drop in the power frequency voltage caused by an impulse wave during the insulation test of break under combined voltage (impulse voltage and power frequency voltage), and a voltage rise of capacitive load during line charging current switching test of the

    Get Price
  • pankaj verma - Chief Manager Substations - Sterlite

    • Working as a civil In-charge for 400/220kv GIS Substation , with jobs in planning and overall co-ordination of all site activities includes Foundation, Erection Stringing Work. • Overall Programing of site activities • Laisoning with Govt. authorities like Forest Department,Title: Chief Manager - Sterlite Power |

    Get Price
  • A Simple Simulation Model for Analyzing Very Fast

    2.1 Model of GIS components Fig. 1 is the cross-section view of a single-phase encapsulated GIS. This configuration is popular in GISs in Vietnam. Binh Tan 220kV GIS, which is the substation under VFTO analyzing in this paper, was also built with this structure and has been in operation since 2012. Fig.1.

    Get Price
  • Khimti-Barhabise-Lapsiphedi 400 kV Substation

    Please provide existing 220kV substation layout drawings and existing 220kV GIS detailed design drawings expecially 220kV GIS main busbar detailed connect drawings. We shall refer those data to make 220kV GIS layout drawing. Shall be provided during detail engineering. 4 Common If existing 220kV GIS have online

    Get Price
  • Chaanling-Xiaojiazhou 220-kV Electric Transmission

    Project. The Cha’anling-Xiaojiazhou 220-kilovolt transmission line will connect the Cha’anling substation with the newly built Xiaojiazhou substation, improving the structure of the power grid in the Xianning District of Hubei, China.

    Get Price
  • 123/145kV SF GAS INSULATED SWITCHGEAR

    for interrupting capacitive charging current, transformer magnetization current, and loop current may be added. A mechanical indicator fixed to the operating shaft inside the operating mechanism box provides a visual means of checking isolator position. Circuit Breakers Circuit breakers are the key modular component of GIS.

    Get Price
  • ODISHA POWER TRANSMISSION CORPORATION

    3 Supply of following POWER CONDUCTORS in the proposed 220KV line with 1.5% provision for sag and wastage as per the technical specification and as per the instruction of the engineer in charge. 3.1 LL-ACSR ZEBRA 490mm(Aluminium clad/Galvanise steel core type) power coductor Kms. 258.95 4 POWER

    Get Price
  • Modeling and Analysis of a 3-Phase 132kv Gas

    The GIS bushing is represented by a capacitance of 200pf. The resistance of 1 ohm spark channel is connected in series with circuit breaker. ESULTS AND DISCUSSIOMATLAB Circuit for 10 mtrs. length in a 3-phase 132Kv GIS shown in the fig. 3 and Sub Circuit of 132 kV GIS fig.4. The proposed method implemented on

    Get Price
  • Risk Assessment on Defects in GIS Based on PD

    The paper, prepared by CIGRE WG D1.03 (TF 09), presents the guidelines for risk assessment procedure on defects in GIS based on PD diagnostics.

    Get Price
  • IOP Conference Series: Materials Science and

    (The 220kV side connected to the 220kVⅣ bus). Hearing ‘flat-flat’ following the electric spark at the connection of GIS case flange, that A and B phase casing connected to the GIS. The voltage waveform record of 220kV side bus is shown below. Figure 2. The voltage waveform record of 500kV transform by 220kV side

    Get Price
  • Policy on the Payment for Maintenance of

    The charge levied for this is commonly known as the Ongoing Service Charge (“OGSC”). Ordinary Service on all cubicles containing GIS switchgear Per Task 4 €4,146 €1,037 Ordinary Service on 110kV cubicles containing 220kV 400kV Transmission Station 1Per Station €40,749 Thermovision Survey Annual

    Get Price
  • Analysis and Calculation of Very Fast Transient

    This paper analyze and Calculates the transient over voltages in 220kv GIS system for 5 mts and 10 mts length during switching operation of circuit breakers and enclosers. MODELING OF GIS COMPONENTFor accurate analysis of transient its is essential to find the VFTOs (Very Fast Transient over voltages) and circuit

    Get Price
  • Aleksandar Krstic - Commissioning and erection Engineer

    Commissioning of 220kV GIS Switchgear-SF6 gas analyzing -Stability test-Contact resistance test - Internalt wirring loop check Low voltage -Battery replacement charging and discharging circle 110VDC-Battery comissioning 110VDC Show more Show less 3x400MVA 400/220kV Substation Al Tebba- Tripoli Libya Nov 2015 -Title: Commissioning and Installation

    Get Price
  • ZF28A TYPE GIS - colprolec.com

    =220kV), whlch is far more strict than the voltage (1.2x145kV = 174kV) specified by IEC standard. To lake advantage of simulation analysis and basic research on the intemal electric field, gas flow field and mechanical properties by the means of finite-element analysis software, the minimizing of the GIS dimension has been achieved.

    Get Price
  • Various Cases and Studies of Direct Stroke Lightning

    BIL = Rated lightening impulse withstand voltage ( For 220kV BIL is 1050 kV/m For 66kV BIL is 450 kV/m ) Is = 9.7 kA. Now, the allowable strike distance is. S = 8 x k x Is. Where, k = Strikes on shield wire (value for mast is 1.2 for earthig wire is 1) S = 25.007m. H = Height of equipment is. H = 12.50m. A = Height of object to beGIS

    Get Price
  • gis cable termination, gis cable termination Suppliers and

    863 gis cable termination products are offered for sale by suppliers on Alibaba.com, of which terminals accounts for 6%. A wide variety of gis cable termination options are available to you, such as crimp terminal, splice. There are 64 suppliers who sells gis cable termination on Alibaba.com, mainly located in Asia.

    Get Price
  • National Grid Substations Technical Specification

    insulated (GIS) substation constructions and covers equipment operated at lower voltages on the same substation site. All NGC plant and a pparatus wholly within the substation and not covered more specifically by other NGTSs is within the scope of this document. 2 REFERENCES The Health and Safety at Work Act 1974. The

    Get Price
  • Hartek Group wins its first GIS substation project

    Nov 14, 2017ShareHartek Power, the EPC arm of the Hartek Group, has won a major order from Haryana Vidyut Prasaran Nigam Ltd for executing a 132kV gas-insulated substation at the 31-acre National Cancer Institute of the All-India Institute of Medical Sciences in Jhajjar, Haryana. This is the first GIS substation project for

    Get Price
  • Pattern Recognition of GIS defects based on

    GIS tank, GIS defect model, traditional partial Fig.2 220kV GIS testing system discharge detecting instrument recommended in IEC0270, UHF measurement system, wide-band oscilloscope, etc. The test of defect models in this paper was accomplished on a 220kv GIS test system in a GIS manufacturer (as shown in

    Get Price
  • Design Installation of EHV/EHV EHV/HV Substations

    Figure 2 – Equipment layout in an AIS substation. When the space available for the installation of the substation is short or when the environmental conditions are extremely severe the usual solution is to install a GIS – Gas Insulated Substation, which schematic diagram is shown in Figure 3.This equipment is a compact

    Get Price
  • INVITATION FOR BID (IFB) (LOCAL COMPETETIVE

    4 220 kV GIS line bays - 08 Nos. at prop. 400 kV Nashik GIS S/s including 02 Nos. of future line bays. 5 220KV GIS Bus Coupler Bay – 01 No. SRM e r-Tender No. T- 1746 MSETCL/CO/DCM/DT/ SS-Pretende (RFx No. 6000000269) Name of S/S Estimated Cost in Rs. Lakhs Completion period in months from date of Site Handing over

    Get Price
  • Latest GETCO Tenders (Gujarat Energy Transmission

    Supply, Erection, Testing Commissioning Of 220kv Lilo Of One Ckt. Of 220kv D/c Amreli - Babara Line At Patkhilori S/s On D/c Tower With Al-59 Conductor With Opgw Cable - 21.65 Km On Turnkey Basis Kishan Suryoday Yojana.

    Get Price
  • Saurabh Pandey - Manager(Projects) - Sterlite Power |

    Professional with 7+years of exposure in EHV transmission line upto 765kV 400/220kV GIS sub-station. My key skills are:-1)Project Execution(Survey,foundation,erection stringing,Ready for charging of EHV transmission line upto 765kV typical hilly terrain) 2)Project Planning 3)ProjectTitle: Manager at Sterlite Powergrid

    Get Price
  • ABB wins $28 million order to upgrade substations in India

    ABB, the leading power and automation technology group, has won an order worth around $28 million from Indias leading transmission company, PowerGrid Corporation of India Ltd (PGCIL), for the extension of three substations in Vadodara, Manesar and Malerkotla, across the countrys eastern and northern regions.

    Get Price
  • Bus transfer current switching define and classification

    Jul 08, 2019The rated bus transfer current of disconnectors used in both air insulated and gas insulated is: for 52kV<Ur<245kV 80 % of the rated continuous current of the disconnector, but limited to 1600A. for 245kV≤Ur≤ 550kV 60% of the rated continuous current of the disconnector, but limited to 4000A. for Ur550kV

    Get Price
  • Rao Amit Singh -PMP - Project Engineer - WSP in the

    220KV/33KV GIS substation. Indias First 220KV Under Ground cable laying Charging. 220KV transmission line. 33KV GIS substation . For power back up erection of 11KV DG sets . Distribution network for Indias First Formula 1 race by Supplying power to 14 no. Outdoor stations 15KM 11KV cable laying .Title: Project Engineer at WSP in the

edge-iconRelated News
toTop
Click avatar to contact us
Chat Online