News Center
SF6 End-of-life Equipment for 64kv

SF6 End-of-life Equipment for 64kv

ABB´s service technicians are continuously trained and certified to handle SF6 and follow correct gas handling procedures. Contact ABB`s to reduces the burden of managing SF6 for all situations where the gas is handled. ABB can address the following end of life needs: Why ABB? Reclaiming gas from decommissioned equipment…

[email protected]
News Detail
  • End of life services for medium voltage equipment

    ABB´s service technicians are continuously trained and certified to handle SF6 and follow correct gas handling procedures. Contact ABB`s to reduces the burden of managing SF6 for all situations where the gas is handled. ABB can address the following end of life needs: Why ABB? Reclaiming gas from decommissioned equipment…

    Get Price
  • by Jean-Marc Deux - Schneider Electric

    End-of-life Recycling for Medium and High Voltage (MV HV) Equipment Schneider Electric White Paper Revision 0 Page 2 When MV and HV electrical equipment insulation or breaker component materials contain Sulphur Hexafluoride (SF 6) and the equipment is near end-of-life, special care must be taken in the recycling

    Get Price
  • SF6 Free HV GIS and Breakers - US EPA

    Purpose Share status on replacement of SF6 with environmentally friendly insulating gas for high voltage GIS and breakers. SDGE, SCE, SMUD, LADWP PGE EPRI ABB, GE, Hitachi Siemens 3M Discussion on the Eco Gas replacement for SF6 November 29, 30 2016 What we learned 2

    Get Price
  • Energies | Free Full-Text | Replacing SF6 in Electrical

    A potential phase-out scenario for high voltage equipment as from 2020, assuming end-of-life equipment replacements and grid expansions should be done by C5-FK or C4-FN technologies, results in a total savings of 4 to 31 Mt of CO 2-eq, with the median at 14 Mt of CO 2-eq, over a subsequent period of 50 years.Cited by: 1

    Get Price
  • Replacing SF6 in Electrical Gas-Insulated

    In this paper, we estimated the SF6 amount to be between 10,800 and 24,700 t (with a mode at 12,700 t) in 2017, resulting in 68 to 140 t of annual emissions from operational leakage only

    Get Price
  • SEC.gov | HOME

    Mar 13, 2015Gross margin for equipment sales for the fourth quarter of 2014 was 9.3%, compared to 22.7% for the corresponding period in 2013. The decrease in gross profit and gross margin were primarily caused by the decrease in sales of relatively higher margin MSAN and MSTP products and decrease in sales of valued

edge-iconRelated News
toTop
Click avatar to contact us