Substation Design Services Extra High Voltage (EHV) Air insulated outdoor switch yard substation design and drawings is our main product for more than last fifteen (15) years. Nowadays the Gas insulated substations (GIS) are gaining popularity due scarcity of sufficient size of land to construct an Air insulated outdoor substation.

[email protected]
News Detail
  • Results of UHF measurements in a 220kV GIS

    tests on a 220kV GIS substation. Prior to the actual tests, measurements were carried to investigate signal attenuation at UHF frequencies and ultrasonic PD detector, it was possible to locate the

    Get Price
  • GAS INSULATED SWITCHGEAR

    ii) Leakage detector iii) Precision pressure gauge h) The required overall parameters of GIS are as follows: SL NO TECHNICAL PARAMETERS 400 KV SYSTEM 220 KV SYSTEM 132 KV SYSTEM 1. Rated Voltage 420 KV (rms) 245 KV (rms) 145 KV (rms) 2. Rated Frequency 50 Hz 50 Hz 50 Hz 3. Grounding

    Get Price
  • sf6 gas gas insulated switchgear Vacuum Charging detecting

    Gas detection is specifed for safe monitoring and measurement of SF6 levels on HV EHV Gas Insulated Switchgear (GIS) and Transformer rooms, 66kV-220kV. Detectors are located inside protected switchgear rooms to provide accurrate monitoring of gas concentrations - usually located in the local gas detection panel,

    Get Price
  • Gas-Insulated-Substations SF6 gas handling

    Sep 26, 2011Siemens GIS, Cable bay with double busbar system including 2 BB DS, 1 line DS, 1 CB, 3 ES High Voltage Substations Source: GIS Factory Berlin. Optimized gas work needs „State-of-the-Art“ equipment – especially on siteespecially on site 6-leakage detectors Sensitive SF 6-leakage detectors to

    Get Price
  • Fault analysis and treatment of 220kV Gas Insulated

    A substation 220kVGIS, junction group YN,d11, products delivered in July 2015. It was put into operation in 2015, and chromatographic tracking test was conducted according to the provisions of maintenance procedures for power transmission and transformation state after operation.

    Get Price
  • Substation Design Services - 400/220/132kV GIS

    Substation Design Services Extra High Voltage (EHV) Air insulated outdoor switch yard substation design and drawings is our main product for more than last fifteen (15) years. Nowadays the Gas insulated substations (GIS) are gaining popularity due scarcity of sufficient size of land to construct an Air insulated outdoor substation.

    Get Price
  • High-voltage substations | Power Transmission | Siemens

    More than 34,500 Siemens GIS bays are currently in operation in GIS substations all over the world – even in most challenging environments. The comprehensive range of GIS for rated voltages from 72.5 kV to 550 kV provides ideal solutions for indoor and outdoor switching applications up to the highest performance rates that require:

    Get Price
  • BHARAT ALUMINIUM COMPANY LIMITED

    2.01.00 400/220KV GIS AIS SUBSTATION 2.01.01 The broad scope under this specification covers establishment of following but not limited to as mentioned below: 1) System Engineering, Design, Manufacture, supply, transportation insurance, storage, Civil work , Erection, testing commissioning complete in all respect for

    Get Price
  • Construction Of 220 Kv Gis S Stn Sec 15 Ii Gurugra

    BOQ for providing new two no. 220kV Gas Insulated Substation (GIS) line bays to accommodate LILO of second circuit of 220kV D/C Badshahpur- Pali line and its jointing with existing 220kV GIS , which is of Siemens make at 220kV GIS S/Stn Sec 65 Gurugram from sr. No. 226 to 300.\n245kV, 2000A, single 3 – ? or three 1 –?,

    Get Price
  • Analysis on the Security Platform of Status

    Analysis on the Security Platform of Status Monitoring and Assessment Technology for Power Grid Equipment Xiangfu Guo1 and Ming Zhong2 1State Grid Henan Electric Power Research Institute, 450052 Zhengzhou Henan, China 2Zhengzhou Gas Power Generation Co., Ltd. 450052 Zhengzhou Henan, China Abstract. The high-speed

    Get Price
  • ABB Rectiformer Substation EPC Package for Qatalum

    † 33/0.4kV distribution for the substation † Fire detection and deluge system for the entire substation † Detailed civil works design and supervision † Interface to the 220kV GIS supplied by ABB Switzerland to the power plant EPC package † Substation controls and protection with the new IEC61850 protocol. The package

    Get Price
  • UHF PD detection in gas-insulated switchgear

    tests on a 220kV GIS substation. Prior to the actual . ultrasonic PD detector, it was possible to locate the partial discharge on-line monitoring system device is widely used in gas

    Get Price
  • GDTF-HTS AC Resonant Test System for Substation -

    Product Description AC Resonant Test System For Substation Electrical Equipment, Is Mainly Composed Of Variable Frequency Power,Exciting Transformers,Reactors, Capacitive Dividers, Which Designed For AC Withstand Voltage Test Of Substation Electric Primary Equipment 220kV Or Below.

    Get Price
  • Ballyvouskill 220/110kv GIS Substation - Gaeltec Utilities

    The project comprise in the of Installation of a new 220/110kV GIS substation located in the townland of Ballyvouskill, approx. 7 km south of Millstreet in Co. Cork.

    Get Price
  • AIS/GIS Substations | NeoDyne Ltd.

    We have designed layouts for 220kV, 110kV, 38kV, 33kV and 20kV substations, both outdoor (AIS) and indoor within buildings (GIS). Through the design process, we verify all HV cable and conductor arrangements to allow for bending radius, mechanical forces during short circuit and electrical loading.

    Get Price
  • Measuring partial discharge in GIS | Think Grid

    To overcome this constraint, a parallel technology was developed, the Gas-Insulated Substation (GIS), using a gas, for example sulphur hexafluoride (SF 6), at high pressure. SF 6 has excellent dielectric properties and is used as the insulating medium between the phases and between the phases and earth. As a

    Get Price
  • SF6 Gas Detection For HV GIS Switchgear - Crowcon F

    Sep 30, 2020Sulphur Hexaflouride (commonly referred to as “SF6”) is an inorganic, colourless, odourless, non-flammable, heavy gas that has exceptional electrical insulation performance. Gas detection is specifed for safe monitoring and measurement of SF6 levels on HV EHV Gas Insulated Switchgear (GIS) and

    Get Price
  • NEPAL ELECTRICITY AUTHORITY

    220kV Lapsiphedi Substation, 132kV Changunarayan Substation and Upgradation of Teku 4 SF6 Gas Leak Detector Set 1 5 Portable Ladder with adustable height as per TS Nos. 1 6 EOT crane for 220kV GIS Hall Set 1 7 EOT crane for 132kV GIS Hall Set 1 I RELAY PANELS (WITH AUTOMATION)

    Get Price
  • SF6 Gas Detection For HV GIS Switchgear - Crowcon F

    Sulphur hexaflouride (commonly referred to as SF6) is an inorganic, colourless, odourless, non-flammable, heavy gas that has exceptional electrical insulation performance. Gas detection is specifed for safe monitoring and measurement of SF6 levels on HV EHV Gas Insulated Switchgear (GIS) and Transformer rooms, 66kV

    Get Price
  • PAPER OPEN ACCESS

    out on the 110kV upper five-line 113 circuit breaker of 220kV** substation. The wind speed is no more than 5 m/s, the temperature is 12 & C, and the humidity is 57%. 3.4.1 Picture of FLIR GF306 infrared thermal imaging leak detector . Using the FLIR GF306 infrared thermal imaging leak detector, it was detected that there was a leak in

    Get Price
  • INDUSTRIAL TRAINING REPORT ON 400/220kV

    The GIS substation at Magarwada is basically a connector between two grids of 400 kV and 220 kV through Inter Connecting Transformers (ICT). The switching and fault protection are broadly done using GIS technology; which requires very less amount of space and maintenance cost. It also gives much better reliability for long period

    Get Price
  • Creation Of 220Kv Substation Nonand Rohtak Tender

    Complete substation automation system for 220/132/33/11 kV substations including hardware (along with transducers) for 9 No. 220 kV, 9 No. 132kV 13 No. 33kV 11kV Incomer present bays and software (for present bays as well as 13 no. 33kV future bays) along with associated equipment for the bays (bay as defined in the

    Get Price
  • Pfisterer | MV CONNEX Cable Plugs Terminations |

    Cable Plugs Terminations MV HV CONNEX. Pfisterer MV HV cable plugs and terminations are suitable for all voltage levels and applications where medium or high voltage power cables must be reliably connected, terminated and distributed within the electricity supply industry.. Pfisterer CONNEX connectors are designed to

    Get Price
  • Estimation of Transient over Voltages in Gas

    respect to 220kv gas insulated substation during switching operation. The effect of Transient field have been analyzed and clearly demonstrated for substation by develop of suitable simulation model to estimate over transient voltages. The proposed approach successfully implemented in the platform of MATLAB software.

    Get Price
  • Muhammad Panah - Construction Manager

    About • Construction Management, 500kV, 380kV, 220kV 132kV GIS / AIS, Static Var Compensator (SVC) Substations,Construction Installation, CCGT Power Plants, Switchgears, HV/LV U/G Cable, Main Reactors, Capaitor Banks, Transformers, Distribution,Transmission line, Industrial and commercial Power Projects.Title: Construction Manager at GE

    Get Price
  • Nexans Cable Leads Keep High Voltage Energy

    Nexans manufactures temporary cables in a variety of lengths across three voltage ranges, 110kV, 132kV and 220kV. Pre-Installed Flexible Silicone Rubber Terminations for Simplified Installations Due to the conditions under which temporary site cables are installed, the cable accessories must be to easy to use and have a wide rangegis

    Get Price
  • Optimising the power system at Qatalum - ABB

    packages. The 220kV Gas Insulated Switchgear (GIS) is within the power plant scope and the 1500m 220kV cable runs are in the rectiformer substation package. As the power plant EPC contractor has awarded the 220kV GIS with its latest control and protection system based on IEC61850 to ABB Switzerland, the substation

    Get Price
  • Substation Design Services - 400/220/132kV GIS

    Consultants of Substation Design Services - 400/220/132kV GIS Substation Design Engineering, 400kV Switchyard Design and Drawings, 220kV Switchyard Design and Drawings and 33kV Switchyard Design offered by Satcon, Kolkata, West Bengal.

    Get Price
  • NEPAL ELECTRICITY AUTHORITY

    Khimti-Barhabise-Lapsiphedi 400 kV Substation Project 400 kV(GIS)/220kV (GIS) New Khimti Substation Item No. Description Estimated Price Schedule No. 1:Plant, and Mandatory Spares Parts to be supplied from abroad Quantity Unit CIP Project Site including insurance, clearing, forwarding and transportation to site (Excluding

    Get Price
  • Pawan Kaushik (Looking Job) - Sr. Designer Electrical

    2x150MW Mecwel Thermal Project + 220kV GIS Substation, A.P. Job Responsibilities: • Preparation of SLD (HT / LT), Electrical Equipment Layout, Central Control Room Layout • Switchyard Layout Up to 765kV, (SLD, Plan, Section, EKD, Earthing Etc. Layouts).Title: Sr. Designer Electrical at

    Get Price
  • GIS 132 Substation | Khitish Moharana -

    GIS 132 Substation. 1.17 Gas filling and Evacuating Plant for 400 kV / 220kV / 132 kV / 66kV GIS units. Page 11 of 63 GETCO/ E/1,2,4,6TS – GIS/R3 Feb 13 1.17.1 All apparatus necessary for filling, evacuating, and recycling the SF6 gas into and from the switch-gear equipment shall be supplied by the bidder to enable any

    Get Price
  • Satcon - Consultants from Newtown, India | Projects

    Prebid-400kV GIS Substations at New Khimti, Barhabise and Lapsiphedi projects of Nepal Electricity Authority, Nepal.(For Pinggao Group Company Ltd., China) Prebid-220/132/33kV GIS substation at Khudi and Manang of Nepal Electricity Authority. (For Pinggao Group Company Ltd., China) 132/33kV Motanga Substation of

    Get Price
  • PAPER OPEN ACCESS

    GIS equipment used in 220kV substation. The three-dimensional finite element simulation model of the test platform is shown in Figure 4. The main part of the drawing is GIS pipeline, which is divided into different gas chambers by pot insulator. An observation window is set up on the pipeline to detect

    Get Price
  • Analysis and Treatment of Typical Problems of GIS

    substation, GIS has the advantages of compact structure, small floor space, high reliability, flexible configuration, convenient and then the leak detector will be used for leak detection. When the leak point is detected by leakage detection of SF6 used in 220kV and below power supply systems. At the actual work site, the

    Get Price
  • Testing Distribution Switchgear for Partial Discharge

    coupling capacitors and conventional PD detectors e.g. according to IEC 60270. Whilst practical and beneficial for factory acceptance testing or further investigation work, this type of testing by its nature is not suited to wide ranging in-field application and owners and operators of electricity distribution networks have

    Get Price
  • TURNKEY TENDER DOCUMENT FOR - Adani Power

    with new latest technology 33kV GIS Switchgear (Boards) associated 33kV Cable laying works at 220kV Aarey, Versova Ghodbunder EHV Substations in phased manner. 2 PROJECT INFORMATION Ambient conditions Design ambient temperature 045 C Primary power supply Incoming supply 220KV, 3PH, 3W, 50Hz, Effectively

    Get Price
  • Muhammad Panah (B.E, PGD) - Construction Manager

    About Site Management, 380kV, 132kV,115kV, 110kV,13.8kV Typical power GIS / AIS SVC-Substations Construction Installation, CCGT Power Plants, Switchgears, HV/LV U/G Cable, Main Reactors, Capaitor Banks, Transformers, Distribution,Transmission line, Industrial and commercial Power Projects.PipelineTitle: Construction Manager

    Get Price
  • Design and Application of a Visualized Fault Joint

    The proposed system introduced a portable intelligent X-ray flaw detector [16-18], which can detect welds and defects inside the GIS, and this technology has played an important role in visualized fault monitoring of disconnectors, transmission rods and other parts of many 110kV/220kV substations.

    Get Price
  • Efficient gis high voltage test At Mouth-Watering Offers

    Outdoor GIS Substation series resonance test system UltraTEV Detector/ Partial discharge detector 500kv gis 12kv gis gis class gis transformer gis testing gis enclosures transformer for gis gis power distribution gis electric gis gas gis 220kv medium voltage switchgear 36kv suppliers medium voltage switchgear low voltage

    Get Price
  • Engineering Consultant - Substations and Transmission

    Direct stroke lightning protection (DSLP) calculation and layout of EHV switchyards, GIS substation buildings, indoor substations and plant electrical rooms. 8. Interlocking diagrams for 400kV, 220kV, 132kV, 33kV switchyards.

    Get Price
  • Mahmoud Farag El Assal - Senior Quality Control

    6. Supervision on installation of 220 (GIS) KV electrical substations. 7. FG system Installation and precommissioning.(GAS Detectors,Flame detectors , smoke detectors,open path gas detectors ). 8. Pre-commissioning and commissioning. 9. Reporting to Electrical commissioning Manager for status of works. 10.Title: Senior Quality Control Engineer

    Get Price
  • Portable Acoustic-Electric Combined System for Partial

    A portable acoustic-electric detection system for GIS partial discharge is developed. This system integrates both high and low-speed data acquisition devices, and is capable of multichannel joint detection of ultra-high-frequency and high-frequency current as well as ultrasonic signal generated during the GIS partial discharge

    Get Price
  • Fault Level of Sub Station in India - CR4 Discussion Thread

    Jan 30, 2018220 kV GIS systems are designed with a fault current of 50 kA. The other important aspect is the time in secs for the fault current. Again 40 kA for 1 sec is designed for Transformer used in the 132 kV System. 50 kA for 1 se for 220 kV System and 31,5 kA for 3 secs are designed.

    Get Price
  • Tata Power-DDL Commissions 66/11 kV GIS Grid

    The substation has an incoming supply from four 66 kV composite circuits emanating 2 Lines from 220KV Badli Grid and 2 Lines from 66KV TPDDL Narela Grid. This grid has been built on 100 per cent pipe foundation and has beens equipped with 2 Power Transformers of 31.5 MVA capacity each, and Nitrogen Injection Fire

    Get Price
  • Saad Elnagar - Senior Electrical Technician - Qatargas

    High voltage Substation {Alstom 220KV GIS} High, Medium, Low voltage Transformers Battery charger ,Motorized valve, Elevator, lighting, Fire detectors, and Firefighting systems. - Using theTitle: Senior Electrical Technician at

    Get Price
  • Invitation for Bids NO. IFB No: [CPC/JICA/ICB/3A/19

    5 Vol III, E3 System Data 220KV Fault Duration - 40kA / 1s 132kV Fault Duration - 31.5kA/ 1s As per Bid Price Schedule, 220kV GIS shall be rated for 50kA/3s and 132kV GIS shall be rated for 40kA/3sec. Please confirm that fault rating for GIS shall be considered as per rating indicated in Bid price schedule and for all other